Equipment Overview

This 60HP Pump Package is fully turnkey; AND for less money than purchasing one NEW. Comes complete with charge pump, 3 bag filter, VFD motors, internally coated 1500# Piping, and fully wired to JB’s. A full 12 month warranty is included along with a comprehensive QA/documentation package. Located in Three Hills, it is available for inspections and short notice delivery via purchase, rental, or rent-to-own options. Pick your plungers and let’s get this moving liquid for you.

This unit is also a perfect candidate for an optional conversion to a pipeline LACT unit. Watch the video walkthrough below as it details the simple adjustments to alternatively convert it from a water injection/disposal application to LACT.

Video Walkthrough

Watch a detailed video tour with Kameron Anderson walking through this water injection/disposal pump package and see specifics on how it can optionally be converted to become a pipeline LACT unit.

Optional Conversion to Pipeline LACT Unit

To optionally convert this to a pipeline LACT unit we would take out the three-bag filter, put in a coriolis, a BS&W, and a three-way valve. This conversion from its current pump package configuration to a LACT unit can be completed in less than three weeks. Contact us to discuss the specifics of this alternative option.

360º Virtual Tour

Explore this package in rich detail through a virtual walkthrough below.

Main Pumps, Motors & Assemblies

P-161 Triplex Pump:​

  • One (1) Reconditioned FMC M12 Triplex Pump​
  • c/w 12 Month Warranty​
  • Client choice of plungers
  • Maximum Continuous RPM Rating:  500RPM​
  • 3” FNPT Suction, 2” FNPT Discharge Connections
  • Rated for 62HP Continuous Duty​
  • 3 Feed Lubricator w/ Oil Reservoir ​
  • Sheave Kit and Belt Guard ​
  • Mounted on sub assembly skid and attached to main skid

Pump Performance

M-161 Motor:​

  • One (1) NEW WEG or TECO 60HP Electric Motor ​
  • TEFC; 1800RPM ​
  • VFD Rated​
  • 600V/3/60VAC​

PD-160 Suction Stabilizer: ​

  • One (1) CoorsTek Suction Pulsation Stabilizers​
  • 300 cu/in​
  • 3” 150# RF​

PD-161 Discharge Stabilizer:​

  • One (1) NEW CoorsTek Discharge Pulsation Stabilizer​
  • 300 cu/in​
  • 2” 1500# RF

P-160 Charge Pump: ​

  • One (1) NEW Grundfos CRN 15-3 Centrifugal Pump​
  • All Wetted Parts Stainless Steel​
  • Rated at 120 gpm @ 50 psi​

M-160 Charge Pump Motor​:

  • One (1) 5 HP WEG Motor ​
  • TEFC, 1200 RPM​
  • 600V/3/60Hz​

F-161 Filter Vessel:​

  • One (1) New P2  3 Bag Filter Vessel​
  • Internally Coated​
  • MAWP 150 PSI @ +300F/-20F​
  • 4” 150# RF in/out Connections ​
  • Rated for 815m3/day​
  • AB/BC/SK CRN Registration
  • Vessel has is new/never used so MB CRN should be easy to have added

Instrumentation

PI-100   P-160 Discharge pressure indicator (0-150 psi)
DPI-100   F-161 Differential Pressure Indicator (0-30 Diff Pres)​
PI-101  F-161 Filter discharge pressure Indicator (0-150 psi)
​PSL-100   P-161 Low suction pressure Shutdown Switch Low (6900GZE14 SET FALLING TO 20 PSI)​
PI-200   P-161 discharge pressure Indicator (0-3000 PSI)
​PSH-200   P-161 High discharge pressure Shutdown Switch High (6900GZE22 SET TBA)
​PSV-200   Pressure Safety Valve (SET RISING TO TBA)​
FT-200   1 ½ x 2 EZ-IN (2” 1500# RF) Turbine Flow Meter
​FQI-200   Flow Totalizer MCIII EX or Equal
​VSH-200   P-161 High Vibration Switch
​LSL-200   P-161 Low Oil Level Shutdown

Piping

Suction Piping:  4” 150# ​

  • Includes 4” Y strainer and Isolation valve​
  • 3” Filter vessel isolation valves and 3” bypass valve​

Discharge Piping: 2” 900/1500​

  • Startup bypass valve manual​
  • Isolation valve​
  • Check valve​
  • PSV and startup bypass valves outlet go back to main pump suction​
  • Drain valves to drain sump​

Drain Piping to be 1” and will drain into open drain sump from:​

  • Basket strainer drain​
  • F-161 Filter vessel drain​
  • Suction piping between P-160/P-161​
  • Discharge piping​
  • P-161 stuffing box drain

Piping Comments

  • All piping internally coated with Devoe 253
  • Built to ASME B31.3 Latest Edition​
  • Discharge piping to be sch. 160​
  • Suction piping to be sch. 80​
  • Piping will include flanges for all connection​
  • All valves will include “Sour Trim”​
  • All piping will include PWHT​
  • All pipe/fittings/bolting/gasket materials to be standard ​

Skid & Building

  • 12’ x 18’ Never Used skid/building.​
  • Checker Plate Flooring​
  • 2” Drip Lip Around Skid​
  • Drain Sump​: High and Low Level Sump Switches, Manual ON/OFF switch​; Filter, Suction and discharge piping, pump stuffing box area drain into sump​
  • Gable Style Building​
  • Ice Rakes​
  • Ridge Vent​
  • Eavestroughs and Downspouts​
  • One (1) Double Man Door​
  • One (1) Single Man Door​
  • 3” Fire Retardant Spray Foam Under skid Insulation Insulated Skid

Electrical

  • Two (2) Interior Lights w/ Switch​
  • Two (2) Exterior Lights w/ Switch​
  • One (1) High Mount Exhaust Fan​
  • One (1) FX4 5KW Ruffneck Heater​
  • One (1) 12V Electrical Receptacle​
  • Two (2) ESD Buttons​
  • Wired to Junction Boxes

QA/QC Documentation

Operation, Parts, Service and QA Manual provided with package c/w:

  • P&ID Dwg’s​
  • Pump Curves​
  • Installation and Operation manual​
  • Parts and service Manual for all equipment​
  • Data sheets for all equipment in package​
  • QC Manual from approved shop with AQP​
  • AB-83​
  • U1A for Filter vessel and Pulsation stabilizers​
  • P&ID​
  • Skid Sketch

Drawings

Download as-built drawings

Additional information

Condition

New/Never Used

Manufactured

2018

Location

Three Hills, AB

Status

Disconnected

Availability

Immediate; 1 Week for Plungers

Service

Sour (Internally Coated)

Piping

4” 150# / 3” 1500#

Electrical

Fully wired

Dimensions

Skidded building is 18’ L x 12’ W

Warranty

c/w 12 month warranty